PURITY 450 Quell ST
PURITY 600 Quell ST
PURITY 1200 Quell ST
MDU – Measuring and Display Unit
Handbook
1 Defi nition of Terms
2 General Information
3 Commissioning a new fi lter with
MDU (Measuring and Display Unit)
4 Replacing the Filter Cartridge
5 Repair
6 Query Mode
7 Troubleshooting
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - PURITY 1200 Quell ST

PURITY 450 Quell STPURITY 600 Quell STPURITY 1200 Quell STMDU – Measuring and Display UnitHandbook 1 Defi nition of Terms 2 General Information 3 Comm

Strany 2

104.2 Inserting the Filter CartridgePlace new fi lter cartridge • 2 in the pressure vessel 1.Check the connector seat of the fi lter cartrigde O-ring i

Strany 3

11Production dataBriefl y press button 1 x (< 1 second), the following message appears.• Serial Appliance Number Battery Service LifeID LevelProduct

Strany 4 - 135 10.12.08

12at the bottom left, the meter reading when changing the cartridge (-1) and at the bottom right, the installation date of the cartridge.Meaning: the

Strany 5 - 12 10.12.08

13Program OverviewID-InformationÀÀÀ00 Current levelÀÀÀ-1 History level 1ÀÀÀ-2 History level 2ÀÀÀ-3 History level 3ÀÀÀ-4 History level 4ÀÀÀE1 Erro

Strany 6

147.2 No or low water fl ow in spite of open water intakeCause: Mains pressure too low.Troubleshooting: Check mains pressure. If the fault continues, c

Strany 7 - 10.12.08

157.9 By-pass setting in the display does not agree with the setting of the by-pass screw (cf. 7.7/7.8 )Cause: Valve strip of the by-pass setting not

Strany 8 - 2346 10.12.08

MAVEA LLC675 Tollgate Road, Suite GElgin, IL 60123 [email protected] in the instruction for use subject to changePN: 536829-M

Strany 9 - 33 10.12.08

2PURITY 450 Quell STPURITY 600 Quell STPURITY 1200 Quell ST050%102030401102187654321112141516171819209121316

Strany 10 - 6 Query Mode

32 General InformationBefore commissioning or replacing the fi lter, please read the system handbook for the PURITY Quell ST Water Filter System. There

Strany 11 - 7784 10.12.08

4Temporary hardnessThe local temporary hardness in gpg (grains per gallon) set during installation of the fi lter system.Note: If necessary, the units

Strany 12 - 06.07.08

5ParameterisationThe following parameters have to be entered:Number of gpg (grains per gallon) or rather mg/L (CaCO3 mg/l).• Filter system size (03Typ

Strany 13 - 7 Troubleshooting

6Press the button (> 2 seconds) until the value for the • temporary hardness rises and keep it pressed until the desired value has been reached.>

Strany 14

7Press button 2 x (< 1 second) to access the next • parameter input type of hardness. Type of hardness fl ashes. > 2 sec10.12.0813gpgUSgaL1212Typ

Strany 15

8Carefully open fl ush valve • 9 while holding the fl ush hose in the bucket. Flush quantity once again at least 2.6 US gallons (10 litres).Close fl ush

Strany 16 - PN: 536829-MAE

9If the cartridge is already exhausted, the capacity is indicated as being negative by fl ashing. No bars are shown in the display.If the monthly limit

Komentáře k této Příručce

Žádné komentáře